Skip to content
Risus Industrial Heating & Cooling Systems

Process Guide

How Does Heat Recovery Work in Pasteurization Systems?

**How Does Heat Recovery Work in Pasteurization Systems?** Is it possible to reuse the energy consumed during pasteurization? Learn how plate heat exchangers enable heat recovery, how energy savings are calculated and how heating and cooling costs can be reduced.

In production facilities processing milk, fruit juice and other liquid food products, pasteurization is an important process for product safety and shelf life. However, heating products to high temperatures and subsequently cooling them requires a significant amount of energy.

Especially in facilities operating continuously, heating and cooling costs can represent a substantial portion of total operating expenses.

Heat recovery in pasteurization systems helps reduce these costs by reusing the thermal energy contained in the product.

But how does heat recovery work in pasteurization systems? How much energy can be saved, and what factors should be considered during system design?

What Is Heat Recovery?

Heat recovery is the process of reusing thermal energy generated during a process or energy that would otherwise need to be removed at the end of a process.

In pasteurization systems, this is achieved by transferring thermal energy from the hot pasteurized product to the incoming cold product.

As a result, the pasteurized product is cooled while the product that has not yet been pasteurized is preheated.

The two product streams do not mix during this process. Heat transfer takes place through the metal surfaces of the heat exchanger.

In pasteurization systems, this application is also known as regenerative heat transfer.

How Does Heat Recovery Work in Pasteurization Systems?

Consider a continuous-flow milk pasteurization system.

Cold milk is pumped from the balance tank into the heat recovery section of the plate heat exchanger. In this section, heat is transferred between hot pasteurized milk and incoming cold milk.

The preheated milk then enters the heating section of the heat exchanger, where it reaches the required pasteurization temperature.

After being held at the specified temperature for the required period, the product is directed back into the heat recovery section.

Here, it transfers part of its thermal energy to the incoming cold milk, reducing its own temperature.

In the final stage, the product enters the cooling section, where it is brought to the required storage temperature.

This system reduces the amount of external energy required for both heating and cooling operations.

What Is the Difference Between Pasteurization Systems With and Without Heat Recovery?

In a pasteurization system without heat recovery, the cold product is heated directly to the pasteurization temperature using hot water or another heating medium.

Once pasteurization is complete, the thermal energy contained in the product is removed by the cooling system.

In this case, a significant portion of the energy used to heat the product is removed from the system without being reused.

In systems equipped with heat recovery, the energy contained in the hot product is used to preheat the incoming cold product.

This reduces the thermal load on steam boilers, hot water generation systems and refrigeration units.

The difference becomes particularly significant in high-capacity production lines operating for extended periods.

How Much Energy Can Be Saved in Pasteurization Systems?

The heat recovery rate depends on heat exchanger design, product characteristics, operating temperatures and system capacity.

Properly designed continuous-flow milk pasteurization systems can achieve heat recovery rates exceeding 90%.

For example, consider a pasteurization line processing 5,000 kilograms of milk per hour.

  • Raw milk inlet temperature: 4°C
  • Pasteurization temperature: 75°C
  • Product capacity: 5,000 kg/h
  • Specific heat capacity of milk: Approximately 3.9 kJ/kg·K

In a system without heat recovery, approximately 385 kW of thermal power is required to heat the milk to the pasteurization temperature.

In an ideal system with 90% heat recovery, the external heating requirement can be reduced to approximately 38.5 kW.

Similarly, the thermal load required to cool the product is significantly reduced.

These figures represent a theoretical calculation. Actual energy consumption may vary depending on environmental heat losses, equipment efficiency, auxiliary systems and operating conditions.

Furthermore, a 90% heat recovery rate does not mean that the facility’s total energy bill will decrease by 90%. The energy consumption of pumps, refrigeration units and other auxiliary equipment must be evaluated separately.

How Is the Heat Recovery Rate Calculated?

In a continuous-flow pasteurization system where the same product flows through both sides at equal flow rates, the heat recovery rate can be approximately calculated using product temperatures.

Heat recovery rate (%) = [(Preheating outlet temperature − Raw product inlet temperature) / (Pasteurization temperature − Raw product inlet temperature)] × 100

For example, if milk enters the system at 4°C and is heated to 68°C in the heat recovery section, with a pasteurization temperature of 75°C, the heat recovery rate is approximately 90.1%.

In this case, the external heating system only needs to heat the milk from approximately 68°C to 75°C instead of from 4°C to 75°C.

This difference clearly demonstrates the importance of heat recovery in pasteurization systems.

Why Are Plate Heat Exchangers Used for Heat Recovery?

Plate heat exchangers are widely preferred in liquid food pasteurization systems due to their compact design and high heat transfer performance.

Specially formed metal plates create suitable flow conditions that support efficient heat transfer.

The main advantages of plate heat exchangers in pasteurization systems include:

  • High heat recovery potential
  • Compact equipment design
  • Integration of multiple process sections within a single frame
  • Compatibility with CIP cleaning in suitable designs
  • Suitability for precise temperature control
  • Easy maintenance and plate replacement in dismantlable models
  • Possibility of capacity expansion under suitable design conditions

However, standard plate heat exchangers may not be suitable for every product.

For highly viscous products or products containing particles and fibres, wide-gap plate heat exchangers or tubular heat exchangers may be more appropriate.

What Factors Affect Heat Recovery Performance?

Heat Transfer Surface Area

The heat transfer surface area of a heat exchanger is one of the main factors affecting its heat recovery capacity.

Achieving higher heat recovery rates generally requires a larger heat transfer surface area.

However, investment costs, pressure drop and operating conditions must be considered together when determining the required surface area.

Product Flow Rate

Operating the system above its designed capacity may prevent the product from reaching the required preheating temperature.

Therefore, heat exchangers should be designed according to actual production capacity.

Physical Properties of the Product

Product viscosity, density, specific heat capacity and thermal conductivity affect the thermal performance of the heat exchanger.

The same heat exchanger design may not always be suitable for different products such as milk, fruit juice, cream and ice cream mixtures.

Cleanliness of Heat Transfer Surfaces

Protein, fat, mineral and other product deposits on the plates may negatively affect heat transfer.

Regular and properly implemented CIP cleaning helps maintain the thermal performance of the system.

Flow Arrangement

In counterflow heat exchangers, hot and cold fluids move in opposite directions.

Under suitable design conditions, this arrangement helps achieve higher heat recovery rates.

Does Heat Recovery Also Reduce Cooling Costs?

Yes. One of the most important advantages of heat recovery is its ability to reduce both heating and cooling requirements.

Instead of being sent directly to the cooling system, the product at pasteurization temperature first transfers a significant portion of its thermal energy to the incoming cold product.

As a result, it reaches the final cooling section at a lower temperature.

This reduces the thermal load on the refrigeration system and, under suitable conditions, may allow the selection of a lower-capacity chiller.

In newly established production facilities, this advantage may positively affect both operating costs and initial investment costs.

Hygiene and Product Safety in Pasteurization Systems With Heat Recovery

In the heat recovery section, raw and pasteurized products flow on opposite sides of the heat exchanger plates.

Therefore, hygienic equipment design, plate integrity, sealing components and pressure control are extremely important.

In milk pasteurization systems, an appropriate positive pressure differential must be maintained on the pasteurized product side to reduce the risk of raw product contaminating pasteurized product in the event of plate damage.

Monitoring pasteurization temperature, verifying holding time and automatically diverting products that have not reached the required temperature are also important for product safety.

Food safety must not be compromised when improving heat recovery efficiency.

Which Industries Use Pasteurization Systems With Heat Recovery?

Pasteurization systems with heat recovery can be used in many industries involving continuous-flow thermal processing.

The main applications include:

  • Milk and dairy production
  • Ayran and drinkable yoghurt production
  • Fruit juice production
  • Ice cream mix preparation
  • Cream production
  • Liquid egg processing
  • Plant-based milk production
  • Tea and coffee-based beverage production
  • Other liquid food and beverage processes

Product characteristics, target temperatures, hygiene requirements and production capacity must be evaluated separately for each application.

What Is the Payback Period of a Pasteurization System With Heat Recovery?

The payback period depends on production capacity, daily operating hours, energy prices and investment costs.

The economic advantages of heat recovery may become more significant in high-capacity facilities operating for extended periods.

When calculating the payback period, both heating energy savings and reductions in cooling energy requirements should be considered.

Maintenance expenses, pump energy consumption and additional equipment costs must also be included in the economic evaluation.

An accurate payback calculation should be based on the facility’s actual operating data.

Conclusion: More Efficient Pasteurization With Less Energy

Heat recovery in pasteurization systems is an effective method of reusing thermal energy consumed during production.

A properly designed system can reduce heating and cooling loads, lower operating costs and improve the efficient use of energy resources.

At Risus Endüstriyel, we provide pasteurization systems with heat recovery and plate heat exchanger solutions for milk, dairy products, fruit juice and other liquid food applications.

Through engineering calculations based on production capacity, product characteristics and target temperatures, energy-efficient systems can be designed to meet the specific requirements of your process.